80-M012PNB008SB-K619C41 preliminary datasheet miniskiip 0 1200v/8a v geon 15 v v geof f -15 v r g on 32 ? r goff 32 ? figure 1 igbt figure 2 fwd typical average static loss as a functi on of output current typical average static loss as a function of output current p loss = f(i out )p loss = f(i out ) t j = 150 c t j = 150 c mi*cos from -1 to 1 in steps of 0,2 mi*cos from -1 to 1 in steps of 0,2 figure 3 igbt figure 4 fwd typical average switching loss typical average switching loss as a function of output current p loss = f(i out ) as a function of output current p loss = f(i out ) t j = 150 c t j = 150 c dc link = 600 v dc link = 600 v f sw from 2 khz to 16 khz in steps of factor 2 f sw from 2 khz to 16 khz in steps of factor 2 output inverter application = = = = 3phase spwm general conditions mi*cosfi = -1 mi*cosfi = 1 0 5 10 15 20 25 0246810121416 iout (a) ploss (w) mi*cosf i= -1 mi*cosfi = 1 0 5 10 15 20 25 0246810121416 iout (a) ploss (w) fsw = 2khz fsw = 16khz 0,0 5,0 10,0 15,0 20,0 25,0 0 2 4 6 8 10 12 14 16 iout (a) ploss (w) fsw = 2khz fsw = 16khz 0,0 1,0 2,0 3,0 4,0 5,0 6,0 7,0 0 2 4 6 8 10 12 14 16 iout (a) ploss (w) copyright vincotech 1 revision: 1
80-M012PNB008SB-K619C41 preliminary datasheet miniskiip 0 1200v/8a figure 5 phase figure 6 phase typical available 50hz output current typical available 50hz output current as a function mi*cos i out = f(mi*cos ) as a function of switching frequency i out = f(f sw ) t j = 150 c t j = 150 c dc link = 600 v dc link = 600 v f sw = 4khz mi*cos = 0,8 t h from 60 c to 100 c in steps of 5 c t h from 60 c to 100 c in steps of 5 c figure 7 phase figure 8 phase typical available 50hz output current as a function of typical available 0hz output current as a function mi*cos and switching frequency i out = f(f sw , mi*cos ) of switching frequency i outpeak = f(f sw ) t j = 150 c t j = 150 c dc link = 600 v dc link = 600 v t h = 80 c t h from 60 c to 100 c in steps of 5 c mi = 0 output inverter application th = 60c th = 100c 0 2 4 6 8 10 12 -1,0 -0,8 -0,6 -0,4 -0,2 0,0 0,2 0,4 0,6 0,8 1,0 mi*cos iout (a) th = 60c th = 100c 0 2 4 6 8 10 12 1 10 100 f sw (khz) iout (a) 1 2 4 8 16 32 64 -1,00 -0,80 -0,60 -0,40 -0,20 0,00 0,20 0,40 0,60 0,80 1,00 iout (a) 11,0-12,0 10,0-11,0 9,0-10,0 8,0-9,0 7,0-8,0 6,0-7,0 5,0-6,0 4,0-5,0 mi*cosfi fsw (khz) th = 60c th = 100c 0 2 4 6 8 10 12 1 10 100 f sw (khz) iout (apeak) copyright vincotech 2 revision: 1
80-M012PNB008SB-K619C41 preliminary datasheet miniskiip 0 1200v/8a figure 9 inverter figure 10 inverter typical available peak output power as a function of typical efficiency as a function of output power heatsink temperature p out =f(t h ) efficiency=f(p out ) t j = 150 c t j = 150 c dc link = 600 v dc link = 600 v mi = 1 mi = 1 cos =0,80 cos =0,80 f sw from 2 khz to 16 khz in steps of factor 2 f sw from 2 khz to 16 khz in steps of factor 2 figure 11 inverter typical available overload factor as a function of motor power and switching frequency p peak / p nom =f(p nom ,f sw ) t j = 150 c dc link = 600 v mi = 1 cos =0,8 f sw from 1 khz to 16khz in steps of factor 2 t h = 80 c motor eff = 0,85 output inverter application 2khz 16khz 0,0 1,0 2,0 3,0 4,0 5,0 6,0 60 65 70 75 80 85 90 95 100 th ( o c) pout (kw) 2khz 16khz 95,0 95,5 96,0 96,5 97,0 97,5 98,0 98,5 99,0 99,5 100,0 0,0 1,0 2,0 3,0 4,0 5,0 6,0 7,0 8,0 9,0 pout (kw) efficiency (%) switching frequency (khz) 100 150 200 250 300 350 400 motor nominal power (hp/kw) overload (%) 1 399 300 200 120 0 0 2 399 300 200 120 0 0 4 399 300 200 120 0 0 8 399 300 200 120 0 0 16 399 300 200 120 0 0 1,50 / 1,10 2,00 / 1,47 3,00 / 2,21 5,00 / 3,68 7,50 / 5,52 10,00 / 7,36 copyright vincotech 3 revision: 1
|